HELUKABEL FIRE-RESISTANT CABLE FOR INDUSTRIES

Fire-resistant cables are widely applied in projects that demand strict safety standards such as high-end apartments, airports, resorts, or office buildings. Specifically, fire-resistant cables are installed in areas that require stable operation for a certain period of time even in the event of fire or explosion, such as emergency exit systems, main power systems, emergency lighting systems, and fire extinguishing systems.

Fire-resistant cables nowadays are designed with protective sheaths made of materials that produce little smoke, do not contain halogens, and do not produce toxic gases when burned. Improvements in upgrading the material of the protective outer layer of fire-resistant cables help minimize the process of producing toxic gases into the environment, causing pollution and directly affecting human health and life.

To ensure the highest quality and safety, fire-resistant cables need to meet many strict international standards. We, HELUKABEL, have been and are accompanying many large projects that require the installation of fire-resistant cables in countries around the world.

Call +84 28 77755578 or email us at info@helukabel.com.vn or register for consultation via the form below to get free advice on various types of control cables, signal cables, etc. with specialized engineers.

1. Instrumentation fire-resistant cables

1. Instrumentation fire-resistant cables

2. Fire-resistant optic cables

2. Fire-resistant optic cables

3. Fire-resistant control cables

3. Fire-resistant control cables

4. Fire-resistant audio cables

4. Fire-resistant audio cables

5. Fire-resistant power cables

5. Fire-resistant power cables

9. Other types of cables used in case of fire

9. Other types of cables used in case of fire

Get a Quote & Expert Consultation

HELUKABEL VIETNAM ZALO OFFICIAL ACCOUNT

Features of some fire-resistant cables from HELUKABEL

1. Fire-resistant optic cables

HELUCOM® A/I-D(ZN)BH(SR)H 4 E9/125 FS90 is a fire-resistant cable with a special structure, with the inner shell material made of FRNC and the cable sheath material made of FR/LSOH. To ensure fire resistance, the cable undergoes rigorous testing and meets the IEC 60331-25 standard to ensure the cable can operate stably for 90 minutes at temperatures up to 750 degrees Celsius.

Cáp quang chống cháy HELUCOM® A/I-D(ZN)BH(SR)H 4 E9/125 FS90

2. HELUTHERM® FR BS 7629 cables

HELUTHERM® FR BS 7629 is widely used in fire alarm or fire detection cable systems, emergency lighting systems in public buildings, office buildings, or places with high-value equipment. HELUTHERM FR® BS 7629 fire-resistant cable aims to ensure the safety of people working in areas with high risk of fire or explosion, while protecting valuables and equipment. The product complies with the Low Voltage Directive 2014/35/EU.

Cáp chống cháy HELUTHERM FRBS 7629

3. HELUDATA® EN-50288-7 FIRE RES OS 500 cables

HELUDATA® EN-50288-7 FIRE RES OS 500 is used in harsh environments that require the transmission of digital signals such as mines, natural gas exploration tunnels, or the petrochemical industry. HELUDATA® EN-50288-7 FIRE RES OS 500 is a fire-resistant cable suitable for installation in dry or wet areas, with open, ventilated spaces and underground networks. In case of fire, the cable ensures stable operation for at least 180 minutes.

Cáp chống cháy HELUDATA® EN-50288-7 FIRE RES OS 500

4. HELUDATA® EN-50288-7 FIRE RES IOS 500 cables

Similar to HELUDATA® EN-50288-7 FIRE RES OS 500, HELUDATA® EN-50288-7 FIRE RES IOS 500 is used to transmit signals in harsh environments such as oil mines, natural gas, and petrochemical industries. Cable elements are made from moisture-resistant materials that can withstand Hydrocarbon impacts. This cable is suitable for installation in dry or wet areas with open, ventilated spaces and underground networks. The product complies with the Low Voltage Directive 2014/35/EU.

HELUDATA® EN-50288-7 FIRE RES IOS 500

5. HELUDATA® EN-50288-7 FIRE RES OSA 500 cables

HELUDATA® EN-50288-7 FIRE RES OSA 500 is a fire-resistant cable that is preferred for installation in harsh environments with a high risk of fire and explosion, such as oil mines, natural gas, and petrochemical industries. This cable uses XLPE insulation material according to EN 50290-2-29 standard.

This cable is suitable for installation in both dry and wet areas and can be installed underground. In case of fire, the cable can ensure stable signal transmission for at least 180 minutes. The product complies with the Low Voltage Directive 2014/35/EU.

Cáp tín hiệu đo lường HELUDATA® EN-50288-7 FIRE RES OSA 500

Find our fire-resistant cables here:

Fire-resistant instrumentation cablesFeaturesPart no.
HELUDATA® EN-50288-7 FIRE RES OS 500XLPE/OS/LS0H11016430
HELUDATA® EN-50288-7 FIRE RES IOS 500XLPE/IS/OS/LS0H11016566
HELUDATA® EN-50288-7 FIRE RES OSA 500XLPE/OS/SWA/LS0H11016406
HELUDATA® EN-50288-7 FIRE RES IOSA 500XLPE/IS/OS/LS0H/SWA/LS0H11016416
HELUTHERM® FR BS 7629High temperature, halogen-free, fire resistant, LPCB certified 
Fire-resistant control cablesOuter sheathTemperaturePart no.CPR class
JZ-500 HMHHalogen-free polymerflexible -25°C to +70°C
fixed -40°C to +70°C
11201Dca
JZ-600 HMH12723Dca
JZ-500 HMH-C11656Dca
JZ-600 HMH-C12850Dca
JB-750 HMHHalogen-free polymerflexible -15°C to +70°C
fixed -40°C to +70°C
11965 
JB-750 HMH-C11942 
HELUCONTROL® JZ-520-HMH LS0H GREY11008617B2ca
HELUCONTROL® JZ-520-HMH-C LS0H GREY11008758B2ca
 Outer sheathTemperaturePart no.
HELUSOUND® Speaker Cable PH 30 LSZHLS0Hflexible -20°C to +90°C
fixed installation -30°C to +90°C
11008297
HELUPOWER® 1000 HY-CARBO SWA FIRE REShydrocarbon resistant PVCflexing -5°C to +50°C
fixed installation -20°C to +90°C
short circuit temperature max. 250°C
17001960
HELUCOM® FS120 A/I-DQ(ZN)(SR)H CcaFR/LSOHOperating, min.: -40°C
Operating, max.: +70°C
11017454
Profibus L2 FRNC 200°C STATIC black 1 x 2 x AWG 23 / 1FRNC-50°C to +200°C805706
In case of fireOuter sheathTemperaturePart no.
HELUPOWER® 1000 HY-CARBOhydrocarbon resistant PVCflexing -5°C to +50°C
fixed installation -20°C to +90°C
short circuit temperature max. 250°C
17001900
HELUPOWER® 1000 HY-CARBO SWA17002000
HELUPOWER® 1000 HY-CARBO SWA EMC17002250
HELUPOWER® 1000 HY-CARBO LEAD GSTAfixed installation -20°C to +70°C
(90°C at the conductor)
short circuit temperature max. 250°C
17002500
HELUPOWER® 1100-RZ1-K LS0H GREENPolyolefin acc. to UNE 21123-4flexible 0°C to +90°C
fixed -15°C to +90°C
11008092
HELUPOWER® THERMFLEX® 145-Singlecross-linked polyolefinflexible -40°C to +120°C
fixed -55°C to +145°C
75486
HELUPOWER® THERMFLEX® 145-C17001676
THERMFLEX® 180 EWKFSpecial siliconeflexible -25°C to +180°C
fixed -60°C to +180°C
74992

Order Now on HELUKABEL E-Store – Fast & Easy!